Lightning Protection & Lightning Arrester Services Across India
Henel Engineers supplies and installs comprehensive lightning protection systems — from ESE air terminals to full earthing networks — for industrial, commercial, and infrastructure projects across India.
Lightning Protection Services
We offer a complete range of lightning protection and earthing services — from initial site assessment and system design through to supply, installation, and ongoing maintenance.
TOPBAS Lightning Protection Products
Henel Engineers is an authorised supplier of TOPBAS lightning protection products, imported from Turkey. TOPBAS manufactures a range of ESE lightning arresters and lightning protection accessories for global markets.
ESE Lightning Arresters

ESE Lightning Arrester
Imported from Turkey
Technical Specifications
TOPBAS SIRIUS ESE Lightning Arrester
Specifications are sourced from TOPBAS product documentation. Consult the official TOPBAS datasheet and a qualified engineer for project-specific design decisions. Henel Engineers does not independently certify these specifications.

ESE Lightning Arrester
Non-Electronic ESE
Features
UMBRAECO ESE Lightning Arrester
Designed and tested as per NF C 17-102 (2011) Standard. Consult a qualified engineer for project-specific design decisions.
Surge Protection Devices (SPD)

Surge Protection Device
Type 1 + 2 SPD, Three Phase
Technical Specifications
Surge Protection Device (SPD)
Consult a qualified engineer for project-specific design decisions.
Earth Rods

Copper Bonded Earth Rod
Earthing Electrode
Product Details
Copper Bonded Earth Rod

GI Earth Rod
Earthing Electrode
Product Details
GI Earth Rod
Earthing Compound

Earthing Compound
TOPBAS Earthing Compound
Product Details
CARBOMAXX Earthing Compound
Conventional Lightning Arresters

Copper Bonded Conventional Lightning Arrester
External Lightning Protection
Product Details
Copper Bonded Conventional Lightning Arrester
Earth Pit Chambers

Earth Pit Chamber Cover
Earthing Pit Cover
Product Details
Earth Pit Cover

Earth Pit Chamber Cover
Earthing Pit Cover
Product Details
FRP Earth Pit Cover
Our Work in the Field






Also looking for windmill operation and maintenance services?
View Windmill & Wind Turbine Maintenance ServicesLightning Protection FAQs
Common questions about ESE lightning arresters, earthing and surge protection in India.
What is an ESE lightning arrester?
An Early Streamer Emission (ESE) lightning arrester is a non-electronic air terminal designed to trigger an earlier upward streamer than a conventional lightning rod, giving it a wider zone of protection. Henel Engineers supplies and installs ESE lightning arresters, including the TOPBAS SIRIUS and UMBRAECO models.
Is Henel Engineers an authorised TOPBAS supplier?
Yes. Henel Engineers is an authorised supplier of TOPBAS lightning protection products, which are imported from Turkey, including ESE lightning arresters, surge protection devices and earthing accessories.
What does a complete lightning protection system include?
A complete lightning protection system typically includes an ESE air terminal or lightning rod, down conductors, an earthing system, surge protection devices, and test joints and accessories — designed to the applicable standards with site-specific risk assessment and zone-of-protection calculations.
What is the difference between an ESE lightning arrester and a conventional lightning arrester?
A conventional (Franklin rod) lightning arrester protects a relatively small area around its tip, while an ESE lightning arrester emits an upward streamer earlier and therefore covers a much larger radius from a single mast. For example, the copper bonded conventional arrester supplied by Henel Engineers has a 5-metre protection radius, whereas the TOPBAS SIRIUS ESE arrester offers a protection radius of up to 107 m (5 m mast, Level IV).
What does "Level IV" mean for a lightning arrester protection radius?
Standards such as NF C 17-102 define four protection levels, from Level I (the most stringent, with the smallest protection radius) to Level IV (the least stringent, with the largest radius). The required level is chosen from a lightning risk assessment of the structure, so the actual radius used in a design depends on the level, mast height and the arrester’s ΔT.
Does a non-electronic ESE lightning arrester need a battery or power supply?
No. Non-electronic ESE lightning arresters such as the TOPBAS SIRIUS and UMBRAECO work without a battery or any external power source, which keeps maintenance simple.
What types of buildings need a lightning protection system?
Henel Engineers provides lightning protection for factories, warehouses, commercial buildings, communication towers and infrastructure facilities. Our field installations also include temples, church steeples, buildings under construction and residential rooftops with solar panels.
Why is earthing important in a lightning protection system?
Earthing gives lightning and fault currents a low-resistance path to dissipate safely into the ground. Without a good earthing system, even a well-placed lightning arrester cannot protect a structure effectively. Henel Engineers designs and installs earthing systems, including chemical earth electrodes and earth pits.
If a building has a lightning arrester, does it still need surge protection?
Yes. A lightning arrester (external lightning protection) protects the structure from a direct strike, but surges can still travel through power and data lines and damage equipment inside. Surge protection devices protect the internal electrical installation, which is why a complete lightning protection system includes both.
What is a Type 1 + 2 surge protection device?
A Type 1 + 2 (Class B + C) SPD combines protection against partial lightning currents (Type 1) and induced surges (Type 2) in a single device, typically installed at the main incoming electrical panel. The TOPBAS TB7K320T12L supplied by Henel Engineers is a three-phase, 3 pole + N, Type 1 + 2 SPD rated 320 VAC (Uc), with 7 kA impulse current (Iimp), 30 kA nominal discharge current (In), a 1.6 kV voltage protection level (Up) and IP20 rating.
Which areas does Henel Engineers serve for lightning protection?
Henel Engineers supplies and installs lightning protection systems for industrial, commercial and infrastructure projects across India.
How do I get a quote for a lightning protection system?
Call +91 94432 82312 or +91 94436 92711, message us on WhatsApp, or use the contact form to share your requirement and request a quote.
Ready to Protect Your Assets?
Whether you need a complete lightning protection system or professional windmill maintenance, our team is ready to discuss your requirement.